Send Message

Remote Control Plane Antenna Indoor Light Motion Sensor

Product Details:
Place of Origin: China
Brand Name: HAISEN
Certification: RoHS CE
Model Number: HT30VR
Payment & Shipping Terms:
Minimum Order Quantity: 100PCS
Price: Negotiable
Packaging Details: Bubble pack, paper flat, outer carton.
Delivery Time: 1-3 days for sample order, 2-3 weeks for bulk order
Payment Terms: L/C, T/T, Western Union
Supply Ability: 100,000pcs Per Month
Specifications Product Description Request A Quote
Specifications
Specifications
Operating Voltage: 220~240 VAC 50/60Hz
Function: Dusk/Dawn Sensor And Dimmable
Output: Constant Current Output
Certificate: CE RoHS
Setting Parameters: By Remote Control
Warranty: 3 Years
Microwave Frequency: 5.8GHz±75MHz
Application: For Ceiling Light And Bulikhead
High Light:

Plane Antenna Indoor Motion Sensor

,

Plane Motion Sensor Dimmer Switch

Product Description

Plane Antenna Remote Control Build-in Dial Code RoHS CE Certification

 

Features:

1.Constant current output.

2.On/off control by relay.

3.Tri-level control by 1-10V output.

4.Suitable for ceiling lights and Bulkhead.

5.Sensitive and reliable.

6.All parameters could be set by remote control.

7.IP 20 and 3 years warranty.

 

Technical data: 

Model number HT30VR
Input voltage 220-240VAC,50Hz/60Hz
Input current 0.18-0.15A Max
Input power 35W Max
Output LED current

0.45A/0.55A/0.60A/0.70A±5%

Output LED voltage

33V-43V DC

Output LED power

Max.30W

Stand-by power

0.5W(230VAC)

Empty load voltage ≤60V DC
Power factor ≥0.9
Efficiency

≥89% (Max.)

Microwave frequency 5.8GHz±75MHz
Microwave power <0.3mW
Detection area 100%/75%/50%/25%
Hold time 5s/30s/1min/3min/5min/10min/20min/30min
Daylight threshold Disable/120Lux/80Lux/50Lux/30Lux/10Lux/2Lux
Stand-by period 0s/10s/30s/1min/5min/10min/30min/+∞
Stand-by dimming level 10%/20%/30%/50%
Mounting height
Max 6m(ceiling mounted)
Deteation range
Max.ø14m (ceiling mounted)
Motion detection 0.5–1.5m/s
Packing method

①the bubble pack,

②paper flat,

③outer carton(400*300*236mm)with drying agent(The sensor 100pcs/carton,gross weight 9.78kg)

Detection angle 30°-150°
Operating temperature

Ta: -20°C~55°C Tc: 85°C

Abnormal protection SCP:Auto recovery,OVP,OCP,OTP
EMC standard EN55015
Safety standard EN61347-1 EN61347-2-13 EN60598-1
IP rating IP 20
Warranty 3 years

 

                                                                                           

On/Off Control             Detection Area                 Hold Time             Daylight Sensor

                                                                                          

Stand-by dimming            Stand-by                 Output Current          Remote Control

level                                  Period

 

Dtection Area:

The fixture indicates teh maximun distance at the highest mounting height with 100% sensitivity.

Typical installation height 2.5-6M.

Mechanical structure:

 

Dimensions:

 

 

Wiring diagram:

 

Daylight periority:

Dusk/Dawn sensor:

Our special active photocell technology can tell the difference between natural light and LED light, to

ensure the light will be off when needed.

With Daylight priority function, HT30V is able to differentiate artificial light brightness from

natural light after installed inside the fixture, and automatically turn off light when ambient
brightness exceeds preset lux level.
 
Precondition of Daylight priority:
1. Standby period is +∞;
2. Standby dimming level is on 10% or 30%;
3. Daylight threshold is on 2Lux, 10Lux or 50Lux.

Lux on/off:

                                   

Light automatically              With insufficient               Lights dims to standby         Light off when

on when ambient                ambient brightness            level if no motion                ambient lux level is

brightness is lower             light dims to 100%              detected after                      higher than preset 

than preset lux level.          when motion                       holdtime.                             Lux mount.

                                          detected.

 

 

 

Application:

1.Automatically ON/OFF function: 

Light on when detect movement and off after people leave at night.Applications:Corridor,Staircase.The daylight threshold is set to"2Lux,10Lux,50Lux".

                   

With sufficient daylight,even          With insufficient daylight,               After the last detection and the 

when motion detected,light            when motion detected,                   present hold time elapsed,

remains OFF.                                 light ON.                                          light OFF.

2.No daylight function:

The daylight threshold is set to"Disable".Light on when detect movement,after people leave,light off after stand-by period,Applications:Dim places such as basement parking ,underpass.

                            

When motion is detected,               After people leave the                   After the last detection and

the sensor will switch on the          detection area,light remains          the present hold time

light to 100% brightness.               100% brightness within                 elapsed,light OFF.

                                                      hold time.

3.Function demo-dimable control/corridor function

                     

With sufficient daylight,even          With insufficient daylight,                After the last detection the light

when motion detected,light            when motion detected,                   will be dimmed down to the 

remains OFF.                                  light ON.                                         stand-by dimming level

                                                                                                             (10% or 30%)after hold time       

After the stand-by period,

light OFF.

Installation Method:

 

Application:

 

User Notes:

1.Microwave can penetrate walls or glass thinner than 20cm and attenuate if thicker than 20cm.
2.The driver voltage shall be stable and float within 10%.
3.Detection area will be affected by speed of motion, mounting height and movement volume.
4.Conduct test on sunny days without the lampshade which will affect the tested lux value.

Remote Control Application:

 

1.Press "ON/OFF button "to turn on the light or off.

2.To reset the parameters,Please follow the steps as below:

  Step 1-press ON,to turn on the light if it was off at the start.

  Step 2-press "Start" to the well-setting sensor

  Step 3-press the button of detection rang,hold time,stand-by dimming level,stand-by period and daylight threshold one after        the other in sequence(press"+/-"to set parameters).

  Step 4-press "Memory" to memorize the settings.

(Note:The interval of each parameter setting shall be controlled within 30s)

3.To programme other lights in the array that have similar sensors to the same programme.

  Step 1-press"ON" to the second sensor

  Step 2-press"Apply".

 

 

 

Remark:Factory default setting:detection area 100%/hold time 5s/daylight threshold disable/satnd-by period 0s/stand-by dimming level 10%.

 

 

 

 

 

 

Get in touch with us
Contact Person : Miss. Evelyn Chow
Tel : 13410390591
Characters Remaining(20/3000)