Send Message

Dimmable 5.8G Microwave Motion Sensor Daylight Movement Detection

Product Details:
Place of Origin: China
Brand Name: HAISEN
Certification: CE RoHS
Model Number: HT30V-I
Payment & Shipping Terms:
Minimum Order Quantity: 100PCS
Price: Negotiable
Packaging Details: bubble pack, paper flat, drying agent,outer carton.
Delivery Time: 1-3 days for sample order, 1-2 weeks for bulk order
Payment Terms: L/C, T/T, Western Union
Supply Ability: 200,000pcs per month
Specifications Product Description Request A Quote
Specifications
Specifications
Usage: Tri-proof Light,battenlight And Panel Light
Output Control Method: ON/OFF / Dimming
Product Name: 5.8G Microwave Motion Sensor
Detection Angle: Less Than Or Equal To 150°
Type: Sensor And Driver Two In One
Power Factor: ≥0.9
Mounting Height: 2.5-6m/8.2-19.68ft(cceiling Mounted)
Warranty: 3 Years
High Light:

5.8G Microwave Motion Sensor

,

ROHS Microwave Motion Sensor

,

5.8G Movement Detection Sensor

Product Description

Dimmable 5.8G Microwave Motion Sensor Daylight Movement Detection

 

Constant Currant Output Daylight Detection Function Motion Sensor

 

Features of Sensor:

1. 5.8GHz microwave motion sensor with dimmable function.

2. Suitable for Tri-Proof light,battenlight and panel light.

3. Detached version flexible installation.

5. Constant current output.

5. 3 years warranty.

 

Product Description of  Movement Detection Sensor​:

Operating voltage 220-240VAC 50Hz/60Hz
Stand-by power ≤1W(230VAC)
THD <20%
Power factor ≥0.9
Efficiency ≥82% (Max.)
Microwave frequency 5.8GHz±75MHz
Microwave power <0.3mW
Function setting mode Dip swith/Remote control
Certificate CE RoHS
Working temperature -20°C~+50°C
IP grade IP 20

                                                                                             

   ON/OFF Control           Detection Area              Hold Time           Daylight Threshold      Warranty of 3 years       

                                                                    

   Stand-by Period    Stand-by Dimming Level    Remote Control      Optional Current                                                                                                          

Mechanical structure of Motion Sensor:

Detection area 50%/100%
Hold time 5s/90s/3min/10min
Daylight threshold 15Lux/Disable
Stand-by dimming level 10%/30%
Stand-by period 0s/30s/10min/+∞
Schema translation Interaction

 

 

 

 

 

Dimensional drawing (Unit: mm) of Motion Sensor:

HD01VR-4 Wire diameter 4mm, Standard Version Cable Length 480±10mm (can be customized).

 

 

Wiring diagram of Motion Sensor:

Input current 0.15A(Max)
Input power 30W (Max)
Output voltage 28V~42V DC
Output current 450mA/500mA/550mA/600mA±5%
Output control method Turn off/dimmer

 

Detection coverage of Motion Sensor:

This figure indicates the maximum distance at the highest mounting height with 100% sensitivity.

Typical installation height 2.5-6m
Detection range Radius 4-7m/13.12-22.96ft
Detection angle ≤150°(without glass)
Mounting height 2.5-6m/8.2-19.68ft(ceiling mounted)

 

 

 

Setting:

 

 

Detection area(1)  
In this area, movement will be detected and able to trigger the sensor. 100% detection area is also known as the strong sensitvity.
Hold time(2,3)  
The period of light keeping 100% brightness after moving objects leave the
detection area.
Daylight threshold(4)  
Definition of the ambient brightness; only when the ambient brightness is lower
than the preset specific lux amount, the sensor will work; when it's preset as
"disable", the sensor works everytime it detects motion regardless the ambient
brightness.
Stand-by dimming level(5,6)  
The definition of low output in the standby period.
Mode selection(7)  
Sensor mode on when the DIP switch is up; sensor mode off when the DIP switch
is down.
Stand-by period(8)  
The period of light keeping low output before it's completely switched off. When
it's preset as"∞“, the light always keep at low output if no movement in the
detection area and doesn't turn off.
 
Application:
1. Automatically ON/OFF function:
Light on when detect movement and off after people leave at night. Applications: Corridor, Staircase.
  With sufficient daylight,even when motion detected,light remains OFF.
  With insufficient daylight,when motion detected, light ON.
  After the last detection and the present hold time elapsed, light OFF.

2. No daylight function

The daylight threshold is set to "Disable".
Light on when detect movement, After people leave, Light off after stand-by period.
If the waiting time is +∞, the lamp is turned off and waits for the next microwave trigger in the waiting brightness state.
  As soon as someone passes the detection area, the light will turn on automatically.
  When the person leaves the detection area, sensor into the delay time, while holding
The light in the room should be 100% bright
Degrees.
  After the delay time, the detection area has no one passes though the detection area,the sensor enter the stand-by period,and the light becomes dim.
  After the stand-by period, there is no one passes through the detection area,, the light goes out.
 
3. Function Demo - Corridor function
  When the ambient light is sufficient, the light will not be on when someone walks in the detection area.
  When the ambient light is insufficient, the detection area detects someone passing the light and turns it on.
  At the end of the delay time, no one passes through the induction zone, and the light becomes dark, entering the waiting time state.
  At the end of the stand-by period, when the sensors no longer detect movement, the lights automatically go out.
 
Attention:
1. Please read the instructions carefully before using this product and keep it well for all users to
read at any time.
2. The sensor should be installed by qualified electrician and ensure power is off before the
installation.
3. We reserve the right to modify any incorrect text, image and necessary technical parameters.
4. Any unauthorized modification is forbidden, otherwise all guarantees will be immediately invalid.
 
Installation precautions:
1. Microwave sensor can be installed in any lamp except the one with full metal shell.
2. The detected surface cannot be shielded by metal objects.
3. Make sure the microwave module is completely exposed outside.
4. The detection surface of the sensor module shall be installed facing the detection area.
5. Should be kept away from the driver to avoid interference generation and lamp flashing.
6. Wiring must be strictly in accordance with the wiring diagram to avoid short circuit.
 
Application Environment:
1. Suitable for indoor installation to avoid false triggering due to external factors such as rain, wind or tree swing.
2. Shall not be installed in the place with all four metal shelters and small space (such as galvanized-iron roof ).
3. Shall note be mounted installation, so as to avoid false trigger caused by the lamp itself shaking.
4. Shall not be installed next to large operating machines such as ventilator/ceiling fan to avoid false triggering caused by machine vibration.
 
User Notes:
1.Microwave can penetrate walls or glass thinner than 20cm and attenuate if thicker than 20cm.
2. The driver voltage shall be stable and float within 10%.
3. Detection area will be affected by speed of motion, mounting height and movement volume.
4. Conduct test on sunny days without the lampshade which will affect the tested lux value.
 

 

Get in touch with us
Contact Person : Miss. Evelyn Chow
Tel : 13410390591
Characters Remaining(20/3000)