New Item Rod Antanna Microwave Sensor For Indoor Ceiling Light Use
Place of Origin | China |
---|---|
Brand Name | HAISEN |
Certification | CE |
Model Number | HD016VCR 3 |
Minimum Order Quantity | 100pcs |
Price | Negotiable |
Packaging Details | Packed in Bubble Bag, Reinforced With Paper Flat, Then Packed With Outer Carton |
Delivery Time | Standard Models Within 3 Weeks |
Payment Terms | D/A, D/P, T/T |
Supply Ability | 1-10pcs Samples Within 2-3 Days; Bulk Order Within 28 Days |
Color | White | Input | 12VDC |
---|---|---|---|
Function | 0-10V Dimming | Programming | DIP Switch |
New Item Rod Antanna Microwave Sensor For Indoor Ceiling Light Use
Features
Slim design, with rod antenna
Powered by 12VDC output
0-10V Dimming
Remote control
Parameter Table
Operating voltage | 7-15V, 12VDC Typical |
Operating Current | ≤30mA |
Stand-by power | ≤0.5W |
Output Control | 0-10V Dimming |
Detection area | 50%/100% |
Hold time | 5S/30S/1min/10min |
Daylight threshold | ON/OFF lux being different |
Stand-by period | 0s/30s/20min/+∞ |
Stand-by dimming level | 10%/20%/30%/50% |
Microwave frequency | 5.8GHz±75MHz |
Microwave power | <0.3mW |
Mounting height | 2.5-4.5m |
Detection range | Radius 3-5m |
Detection angle | 150° Wall Mounted,360° Ceiling Mounted |
Operating temperature | -35°C~+70°C |
IP rating | IP20 |
Life time | 50,000 hours |
Default Program
Can be preset with the DIP switches
Performance
* Bi-Level Dim
When motion is detected, the sensor will switch on the light to 100% brighteness.
After people leave the detection area, light remains 100% brightness for the hold time.
After holdtime, sensor dims light to standby dimming level (10% 20% 30% 50%) and keeps for a standby period.
After standby period,sensors turns OFF the light.
* ON/OFF
When motion is detected, the sensor will switch on the light to 100% brighteness.
After people leave the detection area, light remains 100% brightness for the hold time.
Preset standby period as 0S, sensor turns OFF the light after holdtime.