Product Details:
|
|
| Place of Origin: | China |
|---|---|
| Brand Name: | HAISEN |
| Certification: | CE RoHS |
| Model Number: | HD412S |
|
Payment & Shipping Terms:
|
|
| Minimum Order Quantity: | 100PCS |
| Price: | Negotiable |
| Packaging Details: | bubble pack, paper flat, drying agent,outer carton. |
| Delivery Time: | 1-3 days for sample order, 1-2 weeks for bulk order |
| Payment Terms: | L/C, T/T, Western Union |
| Supply Ability: | 200,000pcs per month |
Wide Pressure 120VAC 60Hz ON OFF Sensor Control Motion Compact Size
Wide Pressure 120VAC 60Hz Control Motion ON OFF Sensor
Setting of ON/OFF sensor:
| Detection area In this area,movement will be detected and able to trigger the sensor.100% detection area is also known as the strong sensitvity. |
|
| Hold-time The period of light keeping 100% brightness after moving objects leave the detection area. |
|
| Daylight threshold Definition of the ambient brightness; only when the ambient brightness is lower than the preset specific lux amount, the sensor will work; when it's preset as "disable",the sensor works everytime it detects motion regardless the ambient brightness. |
|
Features of ON/OFF Sensor:
1. Automatic On/off control with Daylight sensor.
2. Optional detection range, holdtime and daylight threshold .
3. Compact sized particularly suitable for Ceiling lights or Bulkhead.
4. Loop in and loop out for easy installation.
5. 5 years warranty.
Detection area of ON/OFF sensor:
| Motion detection | 0.5~1.5m/s |
| Mounting height | 2-5m (ceiling mounted) |
| Detection angle | ≤150°(Without glass) |
| Detection range | Radius,3-6m (ceiling mounted) |
Mechanical structure of ON/OFF sensor:
| Certificate | RED RoHS CE |
| Detection area | 100%/50% |
| Setting mode | DIP switch |
| Hold time | 5s/60s/3min/10min |
| Daylight threshold | 30Lux/disable |
Dimensions (Unit: mm) of ON/OFF sensor:
| Size | L*W*H:60.6*35.5*25.1MM |
| Operating temperature | -25°C~+60°C |
| Warranty | 5 years |
| Function setting | By 4 dial switvh |
| IP grade | IP 20 |
Wiring diagram of ON/OFF sensor:
| Control mode | ON/OFF |
| Connection type | Amphenol connector(L,N,N,L') |
| Switching capacity | 300W(Impedance load),100W(capacitive load) |
| Stand-by power | ≤0.5W |
| Microwave frequency | 5.8GHz±75MHz |
| Microwave power | <0.3mW |
| Operating voltage | 120VAC 60Hz |
| With sufficient daylight,even when motion detected,light remains OFF. | |
| With insufficient daylight,when motion detected,light ON. | |
| After the last detection,and the present hold time elapsed,light OFF. |
| When motion is detected, the sensor will switch on the light to 100% brighteness. | |
| After people leave the detection area, light remains 100% brightness within hold time. | |
| After the last detection and the present hold time elapsed, light OFF. |