Product Details:
|
|
Place of Origin: | China |
---|---|
Brand Name: | HAISEN |
Certification: | CE |
Model Number: | HT19V |
Payment & Shipping Terms:
|
|
Minimum Order Quantity: | 100PCS |
Price: | Negotiable |
Packaging Details: | Bubble pack, paper flat, outer carton. |
Delivery Time: | 1-3 days for sample order, 1-2 weeks for bulk order |
Payment Terms: | L/C, T/T, Western Union |
Supply Ability: | 200,000pcs per month |
Output Power 12W Dimmable LED Driver Sensor Low Voltage 0.3A 0.35A
Constant Current 0.3A/0.35A LED Driver & Microwave Sensor 2-in-1 Max.12W Ceiling Light
HT19V is a Dark & Dawn 18-36V Output Voltage LED Driver&Microwave Sensor 2-in-1 with Detection Range & Height of 6m(H) x 14m(D), 6-12W Output Power Dimming Function Microwave Motion Detector Suitable for Ceiling Light
Features:
1. Dusk & Dawn Microwave Motion Sensor
2. Dimming Function with 10%/20%/30%/50% Stand-by Brightness
3. Constant Current with options of 0.3A/0.35A
4. Detection Range x Height of 14M x 6M
5. Output Power 12W max. with Voltage of 18-36V
6. Efficiency of 87%
7. Tri-level control by 1-10V output
8. Empty Load voltage of 63V max.
9. Abnormal protection SCP: Auto recovery, OVP, OCP, OTP
10. EMC standardEN55015
11. IP20, 3 years warranty
Product Description
Input voltage |
220~240VAC 50/60Hz |
Input current |
0.078 Max |
Input power |
16W Max |
Detection area |
50%/100% |
Hold time |
5s/60s/ 5min/10min |
Daylight threshold |
2Lux /10Lux /50Lux/Disable |
Stand-by period |
0s/10s/10min /+∞ |
Stand-by dimming level |
10%/30% |
Microwave frequency |
5.8GHz±75MHz |
Microwave power |
<0.3mW |
Detection angle |
30°-150° |
Mounting height |
Max.6m |
Detection range |
Max.ø14m |
Output LED current |
0.3A/0.35A±5% |
Output LED voltage |
18-36V |
Output LED power |
12W Max. |
Empty load voltage |
≤63V |
Power factor |
>0.9 |
Efficiency |
87% (Max.) |
Operating temperature |
Ta: -20°C+50°C Tc: 80°C |
Abnormal protection |
SCP:Auto recovery,OVP,OCP,OTP |
EMC standard |
EN55015 |
Safety standard |
EN61347-1 EN61347-2-13 EN60598-1 |
IP rating |
IP20 |
Life time |
30,000 hours |
Warranty |
3 years |
Detection Range
This figure indicates the maximum distance at the highest mounting height with 100% sensitivity.
Typical installation height 2.5-6m.
Mechanical structure
With eight DIP switch poles to set all parameters
With two DIP switch poles to choose different output current
With two installation hole, easily fixed to the lighting fixture for end user.
Wiring diagram
Two poles to connect with power supply (220-240VAC)
Two poles to connect with LED Light
Dimensions (mm)
DIP Switch Setting
Detection area Hold-time Daylight threshold Stand-by period Stand-by dimming level
In this area, The period of Definition of the The period of light The definition of
movement will light keeping ambient brightness; keeping low output low output in the
be detected 100% brightness only when the before it's standby period.
and able to after moving ambient brightness completely
trigger the objects leave the is lower than the switched off. When
sensor. 100% detection area. preset specific lux it's preset as"∞“,
detection area amount, the sensor the light always
is also known will work; when it's keep at low output
as the strong preset as "disable", if no movement in
sensitvity. the sensor works the detection area
everytime it detects and doesn't turn off.
motion regardless
the ambient brightness.
Output Current Setting
Set the current to be 350mA by plugging black cap on 1&2 PIN, and 300mA by plugging on 2&3 PIN.
Daylight Priority
With Daylight priority function, HT19V-I is able to differentiate artificial light brightness
from natural light after installed inside the fixture, and automatically turn off light when
ambient brightness exceeds preset lux level.
Precondition of Daylight priority:
1. Standby period is +∞;
2. Standby dimming level is on 10% or 30%;
3. Daylight threshold is on 2Lux, 10Lux or 50Lux.
Application Demo
1. Automatically ON/OFF function:
Light on when detect movement and off after people leave at night. Applications: Corridor, Staircase.
The daylight threshold is set to "2lux,10lux,50lux"
With sufficient daylight, With insufficient daylight, After the last detection and
even when motion detected, when motion detected, light ON. the present hold time
light remains OFF. elapsed, light OFF.
2. No daylight function
The daylight threshold is set to "Disable".
Light on when detect movement, After people leave, Light off after stand-by period.
Applications: Dim places such as Basement Parking, Underpass.
When motion is detected, After people leave the detection After the last detection and
the sensor will switch on the area, light remains 100% the present hold time
light to 100% brighteness. brightness within hold time. elapsed, light OFF.
3. Function Demo - Dimmable control/Corridor function
With sufficient daylight, With insufficient After last detection, After the stand-by
even when motion daylight, when motion light will be dimmed period, light OFF.
detected, light remains detected, light ON. down to the stand-by
OFF. dimming level (10% or
30%) after holdt
User Notes:
1. The detected surface cannot be shielded by metal objects.
2. Make sure the microwave module is completely exposed outside.
3. The detection surface of the sensor module shall be installed facing the detection area.
4. Wiring must be strictly in accordance with the wiring diagram to avoid short circuit.