Product Details:
|
|
| Place of Origin: | China |
|---|---|
| Brand Name: | HAISEN |
| Certification: | CE UKCA |
| Model Number: | ES-EOES SERIES |
|
Payment & Shipping Terms:
|
|
| Minimum Order Quantity: | 100pcs |
| Price: | Negotiable |
| Packaging Details: | Packed in Bubble Bag, Reinforced With Paper Flat, Then Packed With Outer Carton |
| Delivery Time: | Standard Models Within 3 Weeks |
| Payment Terms: | D/A, D/P, T/T |
| Supply Ability: | 1-10pcs Samples Within 2-3 Days; Bulk Order Within 28 Days |
Features
-battery overcharge protection
-battery over-discharge protection
-output overload protection
-short-circuit protection
Parameter Table
| Input voltage | 220-240 Vac 50/60Hz |
| Input Current | 0.03A(Max) 230V AC |
| Input Power |
<4W
|
| Power Factor | ≥0.5@230Vac |
| Battery charging current | 300mA(Max) |
| Battery charging time | 24h(Max) |
| Working humidity | 20-80%RH(No Condensation) |
| Working temperature | -20-60°C |
| Maximum shell temperature | 75°C |
| Storage temperature | -20-40°C |
| Electric strength | 3000Vac 5mA(input to output) |
| IP Rating | IP20 |
| Warranty |
3 Years |
|
LED Indicator
|
Yellow on
|
The battery discharge time is insuffificient
|
Main power supply
|
|
The yellow indicator
blinks at 1Hz
|
The battery is open circuit or the charging circuit is short-circuited
|
||
|
The yellow indicator
blinks at 3Hz
|
The Led fifixture is open circuit ,
short circuit or no output when in the self-test state
|
||
|
Red on
|
Battery charging
|
||
|
Red off
|
Battery stop charging
|
||
|
Green on
|
In main power mode
|
||
|
The green indicator
blinks at 1Hz
|
Monthly self-test status
|
||
|
The green indicator
blinks at 3Hz
|
Annual self-test status
|
||
|
The green indicator
blinks two times
|
Fast manual monthly/annual self-test
|
||
|
LED indicator off
|
Emergency status
|
Battery supply
|
|
|
The yellow indicator
blinks at 3Hz
|
The Led fifixture is open circuit ,short circuit,after 2 seconds,the output is turned off and the battery enters the standby state,
need to reconnect the mains and then timing into normal operation
|
||
|
Yellow on
|
Battery capacity is low
|
||
|
Test button
|
1S<Key≦3S
|
Green off,enter simulated emergency,maintain emergency status
for 10S and exit
|
Main power
supply
|
|
3S<Key≦5S
|
The green indicator blinks at 1Hz,enter the monthly self-test,
maintain the emergency status for 120S and exit
|
||
|
5S<Key≦7S
|
The green indicator blinks at 3Hz,enter the Annual self-test,
keep to low battery voltage and exit
|
||
|
Double click
|
The green indicator blinks two times,quickly view the monthly
self-inspection and annual self-inspection, and automatically enter
the annual self-inspection after 11 times of monthly inspection
|
||
|
3S<Key
|
Exit the emergency state and enter the standby state,need to
reconnect the mains and then timing into normal operation
|
Battery supply
|
Model Selection table
| Model No. | Input voltage | Output voltage | Output Current | Lithium battery | Emergency time |
Emergency power
|
|
ES-EOE03-01S-120V
|
220-240Vac 50/60Hz |
12-120V DC
|
20-60mA
|
3000mAh/3.7V | 3Hrs | 3W |
|
ES-EOE03-01S-200V
|
220-240Vac 50/60Hz |
50-200V DC
|
30-10mA
|
3000mAh/3.7V | 3Hrs | 3W |
Dimension (Unit:mm)
![]()
Wiring Diagram
![]()